Atlas Copco Stationary Air CompressorsImportant1. This book applies to the compressors from serial numberAIF-024 378 onwards.2. This book must be used
2920 1251 0210Instruction bookOil stop valve (Vs) prevents compressor element (E) fromflooding with oil when the compressor is stopped.Valve (BV) by-
2920 1251 0211Instruction bookAF. Air filter(s)AR. Air receiver/oil separatorAV. Air outlet valveBV. Thermostatic by-pass valve(s),oil cooler(s)Ca. Ai
2920 1251 0212Instruction book1.3.5 Regulating systemThe system is controlled by Elektronikon® regulator (CM)which keeps the net pressure within pro
2920 1251 0213Instruction bookoutlet of compressor element (E) decreases, valve (V3)closes by spring force and stops blowing off air.7. Valve (V2) all
2920 1251 0214Instruction book1.3.5.2 LoadingWhen the net pressure decreases to the lower limit of theworking pressure (loading pressure), solenoid v
2920 1251 0215Instruction bookFig. 6b. Dimension drawing GA W 90 and -110Fig. 6c. Dimension drawing GA132 and -160
2920 1251 0216Instruction bookFig. 6d. Dimension drawing GA W 132 and -160Fig. 6e. Dimension drawing GA200 up to -315
2920 1251 0217Instruction book2.2 Installation proposal (Fig. 7)1. Install the compressor on a level floor suitable for takingthe weight of the compre
2920 1251 0218Instruction bookFig. 7. Installation proposal
2920 1251 0219Instruction bookV = recommended air net volume in ldP = pressure difference between unloading andloading pressures in bar (recommendedmi
2920 1251 022Instruction bookThis instruction book describes how to handle the machines to ensure safe operation, optimum efficiency and long service
2920 1251 0220Instruction book2.3 Electric cablesRemarks- The size is valid for cable PVC 70°C at ambient 40°Caccording to EN60204, except for 60 Hz
2920 1251 0221Instruction bookFig. 9a IEC/VDE
2920 1251 0222Instruction bookFig. 9b 60 Hz CSA/ULFigs. 9. Electrical connections (typical examples)
2920 1251 0223Instruction book2.3.4 GA/GA W - 60 Hz compressors for Canada/USACompressor type Mains + earth cable in mm2440/460 V 575 V90 3xMCM250 + A
2920 1251 0224Instruction bookFigure 10b shows pictographs which may be stuck on or insidethe bodywork:23 Water outlet24 Manual condensate drain25 Wa
2920 1251 0225Instruction book3 OPERATING INSTRUCTIONSSafety precautionsThe operator must apply all related safety precautions includingthose mentione
2920 1251 0226Instruction book7. Remove filler plugs (FC2-Fig. 1b). Pour approx. 1 l(0.25 US gal) of oil into the compressor elements (usethe bottl
2920 1251 0227Instruction book3.5 During operation (Fig. 3a)1. When automatic operation LED (1) is alight, starting andstopping of the motor is contro
2920 1251 0228Instruction bookWarningBefore carrying out any maintenance, repair or adjustment,stop the compressor, press emergency stop button (S2-F
2920 1251 0229Instruction book4 MAINTENANCEWarningBefore carrying out any maintenance or repair, press stop button (9-Fig. 3a), wait until the compres
2920 1251 023Instruction book1 LEADING PARTICULARS1.1 General descriptionGA90 up to GA315 and GA90 W up to GA315 W are single-stage, oil-injected scre
2920 1251 0230Instruction bookNotes1. In very dusty surroundings it may be necessary to check and replace the air filters more frequently. Consult A
2920 1251 0231Instruction book3. Clean the filter seats on the manifold. Oil the gaskets ofthe new filters and screw them into place until the gasket
2920 1251 0232Instruction book4.7 Service kitsService kitsService kits comprise all parts needed for servicing componentsand offer the benefits of ge
2920 1251 0233Instruction book6 PROBLEM SOLVINGWarningBefore carrying out any maintenance or repair, press stopbutton (9-Fig. 3a), wait until the comp
2920 1251 0234Instruction book7.3 Settings of safety valves- 12 bar(e) for 7.5 bar, 10 bar, 100 psi, 125 psi and 150 psi versions- 15 bar(e) for 13 b
2920 1251 0235Instruction bookGA/GA W Motor Supply Max. setting Max. fuse ratingsCompressor Type voltage overload IEC Class IEC Class CSA HRC UL
2920 1251 0236Instruction book7.4.4 Fan motor circuit breakers for GA - 50 HzGA Compressor type Supply voltage (V) Maximum setting of circuit breaker
2920 1251 0237Instruction book7.5.3 Specific data of GA/GA W 90 up to -160 7.5 bar - 50 Hz 1)Compressor type 90 110 132 160 90 W 110 W 132 W 160 WM
2920 1251 0238Instruction book7.5.6 Specific data of GA/GA W 90 up to -160 100 psi - 60 Hz 1)Compressor type 90 110 160 90 W 110 W 160 WMaximum
2920 1251 0239Instruction book7.5.9 Specific data of GA/GA W 90 up to -160 200 psi - 60 Hz 1)Compressor type 90 110 160 90 W 110 W 160 WMaximum wor
2920 1251 024Instruction bookFig. 1a GA90AF. Air filterAR. Air receiver/oil separatorCa. Air coolerCo. Oil coolerCV. Check valveDP1. Oil drain plug,
2920 1251 0240Instruction book7.5.12 Specific data of GA/GA W 200 up to -315 100 psi - 60 Hz 1)Compressor type 200 250 315 200 W 250 W 315 WMaximu
2920 1251 0241Instruction book7.5.15 Specific data of GA/GA W 250 and -315 200 psi - 60 Hz 1)Compressor type 250 315 250 W 315 WMaximum working pre
2920 1251 025Instruction book1.2.1.4 Automatic restart after voltage failureFor compressors leaving the factory, this function is madeinactive. I
2920 1251 026Instruction bookF1/F2. FusesF3/F5. Circuit breakersF21. Overload relay, drive motor (M1)K15/16. Fan motor contactors 1)K21. Line contact
2920 1251 027Instruction book1.2.2 Control panel (Fig. 3a)Indicators, keys and buttonsRef. Designation1 Automatic operation Indicates that the regu
2920 1251 028Instruction bookDesignation Function(4-Fig. 3a)Load To load the compressor manuallyMain Screen To return from a menu to the main display
2920 1251 029Instruction bookin compressor element (E). Compressed air and oil aredischarged to air receiver/oil separator (AR) via check valve(CV).